    Characterization of Stapes Anatomy: Investigation of Human and Guinea Pig

    Get PDF
    The accuracy of any stapes model relies on the accuracy of the anatomical information upon which it is based. In many previous models and measurements of the stapes, the shape of the stapes has been considered as symmetric with respect to the long and short axes of the footplate. Therefore, the reference frame has been built based upon this assumption. This study aimed to provide detailed anatomical information on the dimensions of the stapes, including its asymmetries. High-resolution microcomputed tomography data from 53 human stapes and 11 guinea pig stapes were collected, and their anatomical features were analyzed. Global dimensions of the stapes, such as the size of the footplate, height, and volume, were compared between human and guinea pig specimens, and asymmetric features of the stapes were quantitatively examined. Further, dependence of the stapes dimensions on demographic characteristics of the subjects was explored. The height of the stapes relative to the footplate size in the human stapes was found to be larger than the corresponding value in guinea pig. The stapes showed asymmetry of the footplate with respect to the long axis and offset of the stapes head from the centroid of the medial surface of the footplate for both humans and guinea pigs. The medial surface of the footplate was curved, and the longitudinal arches of the medial surface along the long axis of the footplate were shaped differently between humans and guinea pigs. The dimension of the footplate was gender-dependent, with the size greater in men than in wome

    Multiphoton imaging for morphometry of the sandwich-beam structure of the human stapedial annular ligament

    Full text link
    Background The annular ligament of the human stapes constitutes a compliant connection between the stapes footplate and the peripheral cochlear wall at the oval window. The cross section of the human annular ligament is characterized by a three-layered structure, which resembles a sandwich-shaped composite structure. As accurate and precise descriptions of the middle-ear behavior are constrained by lack of information on the complex geometry of the annular ligament, this study aims to obtain comprehensive geometrical data of the annular ligament via multiphoton imaging. Methods The region of interest containing the stapes and annular ligament was harvested from a fresh-frozen human temporal bone of a 46-years old female. Multiphoton imaging of the unstained sample was performed by detecting the second-harmonic generation of collagen and the autofluorescence of elastin, which are constituents of the annular ligament. The multiphoton scans were conducted on the middle-ear side and cochlear side of the annular ligament to obtain accurate images of the face layers on both sides. The face layers of the annular ligament were manually segmented on both multiphoton scans, and then registered to high-resolution μCT images. Results Multiphoton scans of the annular ligament revealed 1) relatively large thickness of the core layer compared to the face layers, 2) asymmetric geometry of the face layers between the middle-ear side and cochlear side, and variation of their thickness and width along the footplate boundary, 3) divergent relative alignment of the two face layers, and 4) different fiber composition of the face layers along the boundary with a collagen-reinforcement near the anterior pole on the middle-ear side. Conclusion and outlook Multiphoton microscopy is a feasible approach to obtain the detailed three-dimensional features of the human stapedial annular ligament along its full boundary. The detailed description of the sandwich-shaped structures of the annular ligament is expected to contribute to modeling of the human middle ear for precise simulation of middle-ear behavior. Further, established methodology in this study may be applicable to imaging of other middle-ear structures. Keywords Annular ligament Stapes Multiphoton microscopy Two-photon microscopy Face layer Core laye

    Complex Stapes Motions in Human Ears

    Get PDF
    It has been reported that the physiological motion of the stapes in human and several animals in response to acoustic stimulation is mainly piston-like at low frequencies. At higher frequencies, the pattern includes rocking motions around the long and short axes of the footplate in human and animal ears. Measurements of such extended stapes motions are highly sensitive to the exact angulation of the stapes in relation to the measurement devices and to measurement errors. In this study, velocity in a specific direction was measured at multiple points on the footplates of human temporal bones using a Scanning Laser Doppler Vibrometer (SLDV) system, and the elementary components of the stapes motions, which were the piston-like motion and the rocking motions about the short and long axes of the footplate, were calculated from the measurements. The angular position of a laser beam with respect to the stapes and coordinates of the measurement points on the footplate plane were calculated by correlation between the SLDV measurement frame and the footplate-fixed frame, which was obtained from micro-CT images. The ratios of the rocking motions relative to the piston-like motion increased with frequency and reached a maximum around 7kHz. A novel method for quantitatively assessing measurements of complex stapes motions and error boundaries of the motion components is presented. In the frequency range of 0.5 to 8kHz, the magnitudes of the piston-like and two rocking motions were larger than estimated values of the corresponding upper error bound

    Three-dimensional Quasi-Static Displacement of Human Middle-ear Ossicles under Static Pressure Loads: Measurement Using a Stereo Camera System

    Full text link
    The time delay and/or malfunctioning of the Eustachian tube may cause pressure differences across the tympanic membrane, resulting in quasi-static movements of the middle-ear ossicles. While quasi-static displacements of the human middle-ear ossicles have been measured one- or two-dimensionally in previous studies, this study presents an approach to trace three-dimensional movements of the human middle-ear ossicles under static pressure loads in the ear canal (EC). The three-dimensional quasi-static movements of the middle-ear ossicles were measured using a custom-made stereo camera system. Two cameras were assembled with a relative angle of 7 degrees and then mounted onto a robot arm. Red fluorescent beads of a 106-125 µm diameter were placed on the middle-ear ossicles, and quasi-static position changes of the fluorescent beads under static pressure loads were traced by the stereo camera system. All the position changes of the ossicles were registered to the anatomical intrinsic frame based on the stapes footplate, which was obtained from µ-CT imaging. Under negative ear-canal pressures, a rotational movement around the anterior-posterior axis was dominant for the malleus-incus complex, with small relative movements between the two ossicles. The stapes showed translation toward the lateral direction and rotation around the long axis of the stapes footplate. Under positive EC pressures, relative motion between the malleus and the incus at the IMJ became larger, reducing movements of the incus and stapes considerably and thus performing a protection function for the inner-ear structures. Three-dimensional tracing of the middle-ear ossicular chain provides a better understanding of the protection function of the human middle ear under static pressured loads as immediate responses without time delay. Keywords ambient pressure variation micro-computed tomography imaging middle-ear ossicles protection function quasi-static displacement static pressure static pressure loads stereo camera system three-dimensional displacemen

    The influence of postoperative tissue formation on sound transmission after stapes surgery

    Full text link
    In the surgical treatment of otosclerosis, the coupling between the stapes prosthesis and the long process of the incus is critical. After surgery, connective tissue and mucosa may grow over the coupling area and thereby influence the sound transmission properties of the incus-prosthesis interface. It was the hypothesis of this study that tissue ongrowth in the incus-prosthesis interface has little influence on sound transmission following stapes surgery. The goals of the study were to: (1) investigate the extent of postoperative tissue ongrowth over the stapes prosthesis; (2) objectively evaluate intra- and postoperative sound transmission properties of revision stapes surgery and compare the findings to those from primary surgery; (3) quantify the influence of ongrown tissue on sound transmission after stapes surgery. A group of 10 patients undergoing revision stapes surgery was investigated with audiological evaluations and intraoperative laser Doppler interferometry, and with scanning electron microscopy of the explanted incus with its adherent prosthesis in 6 patients. Results were compared to a group of patients undergoing primary otosclerosis surgery and temporal bone experiments. Results indicated that tissue grows over the prosthesis, as identified in all specimens. Sound transmission properties were evaluated intraoperatively (i.e., incus mobility and prosthesis-fixation quality), and found to correlate well with the functional hearing results. Ongrowing mucosa in the incus-prosthesis interface had only a minimal effect on sound transmission properties and cannot compensate adequately for insufficient prosthesis fixation. Therefore, it is essential that the stapes prosthesis is properly fixed during primary otosclerosis surgery

    Contribution of the flexible incudo-malleal joint to middle-ear sound transmission under static pressure loads

    Get PDF
    The incudo-malleal joint (IMJ) in the human middle ear is a true diarthrodial joint and it has been known that the flexibility of this joint does not contribute to better middle-ear sound transmission. Previous studies have proposed that a gliding motion between the malleus and the incus at this joint prevents the transmission of large displacements of the malleus to the incus and stapes and thus contributes to the protection of the inner ear as an immediate response against large static pressure changes. However, dynamic behavior of this joint under static pressure changes has not been fully revealed. In this study, effects of the flexibility of the IMJ on middle-ear sound transmission under static pressure difference between the middle-ear cavity and the environment were investigated. Experiments were performed in human cadaveric temporal bones with static pressures in the range of +/- 2 kPa being applied to the ear canal (relative to middle-ear cavity). Vibrational motions of the umbo and the stapes footplate center in response to acoustic stimulation (0.2-8 kHz) were measured using a 3D-Laser Doppler vibrometer for (1) the natural IMJ and (2) the IMJ with experimentally-reduced flexibility. With the natural condition of the IMJ, vibrations of the umbo and the stapes footplate center under static pressure loads were attenuated at low frequencies below the middle-ear resonance frequency as observed in previous studies. After the flexibility of the IMJ was reduced, additional attenuations of vibrational motion were observed for the umbo under positive static pressures in the ear canal (EC) and the stapes footplate center under both positive and negative static EC pressures. The additional attenuation of vibration reached 4~7 dB for the umbo under positive static EC pressures and the stapes footplate center under negative EC pressures, and 7~11 dB for the stapes footplate center under positive EC pressures. The results of this study indicate an adaptive mechanism of the flexible IMJ in the human middle ear to changes of static EC pressure by reducing the attenuation of the middle-ear sound transmission. Such results are expected to be used for diagnosis of the IMJ stiffening and to be applied to design of middle-ear prostheses

    Round Window Reinforcement-Induced Changes in Intracochlear Sound Pressure

    Full text link
    Introduction: The round window membrane (RWM) acts as a pressure-relieving membrane for incompressible cochlear fluid. The reinforcement of the RWM has been used as a surgical intervention for the treatment of superior semicircular canal dehiscence and hyperacusis. The aim of this study was to investigate how RWM reinforcement affects sound pressure variations in the cochlea. Methods: The intracochlear sound pressure (ICSP) was simultaneously measured in the scala tympani (ST) and scala vestibuli (SV) of cadaveric human temporal bones (HTBs) in response to acoustic stimulation for three RWM reinforcement materials (soft tissue, cartilage, and medical-grade silicone). Results: The ICSP in the ST was significantly increased after RWM reinforcement for frequencies below 2 kHz. Between 400 and 600 Hz, all three materials demonstrated the highest median pressure increase. The higher the RWM stiffness, the larger the pressure increase: silicone (7 dB) < soft tissue (10 dB) < cartilage (13 dB). The ICSP in the SV was less affected by reinforcement. The highest median pressure increase was 3 dB. The experimental findings can be explained with numerical models of cochlear mechanics. Discussion and conclusions: RWM reinforcement increases the sound pressure in ST at lower frequencies but only has a minor influence on the SV pressure

    The influence of prosthesis diameter in stapes surgery: a meta-analysis and systematic review of the literature

    Full text link
    A 0.6-mm diameter piston prosthesis is associated with significantly better results than a 0.4-mm prosthesis and should be used if the surgical conditions allow it

    Contribution of the flexible incudo-malleal joint to middle-ear sound transmission under static pressure loads

    No full text
    The incudo-malleal joint (IMJ) in the human middle ear is a true diarthrodial joint and it has been known that the flexibility of this joint does not contribute to better middle-ear sound transmission. Previous studies have proposed that a gliding motion between the malleus and the incus at this joint prevents the transmission of large displacements of the malleus to the incus and stapes and thus contributes to the protection of the inner ear as an immediate response against large static pressure changes. However, dynamic behavior of this joint under static pressure changes has not been fully revealed. In this study, effects of the flexibility of the IMJ on middle-ear sound transmission under static pressure difference between the middle-ear cavity and the environment were investigated. Experiments were performed in human cadaveric temporal bones with static pressures in the range of +/- 2 kPa being applied to the ear canal (relative to middle-ear cavity). Vibrational motions of the umbo and the stapes footplate center in response to acoustic stimulation (0.2-8 kHz) were measured using a 3D-Laser Doppler vibrometer for (1) the natural IMJ and (2) the IMJ with experimentally-reduced flexibility. With the natural condition of the IMJ, vibrations of the umbo and the stapes footplate center under static pressure loads were attenuated at low frequencies below the middle-ear resonance frequency as observed in previous studies. After the flexibility of the IMJ was reduced, additional attenuations of vibrational motion were observed for the umbo under positive static pressures in the ear canal (EC) and the stapes footplate center under both positive and negative static EC pressures. The additional attenuation of vibration reached 4~7 dB for the umbo under positive static EC pressures and the stapes footplate center under negative EC pressures, and 7~11 dB for the stapes footplate center under positive EC pressures. The results of this study indicate an adaptive mechanism of the flexible IMJ in the human middle ear to changes of static EC pressure by reducing the attenuation of the middle-ear sound transmission. Such results are expected to be used for diagnosis of the IMJ stiffening and to be applied to design of middle-ear prostheses